SCOPE

Power transformers:

  • Dissipation factor/ Power Factor/ Tan Delta and Capacitance of windings and bushings with frequency sweep and voltage sweep “tip-up”.
  • Winding Resistance
  • Turn Ratio
  • Exciting current.
  • Short circuit impedance
  • Demagnetization
  • Dielectric frequency response analysis / DFRA /frequency dielectric spectroscopy / FDS
  • Frequency Response Analysis/ SFRA
  • Current transformers analysis.
  • Insulation Resistance / Polarized Index.
  • Partial discharge analysis on-line and off-line.

• Instrument transformers

  • Current transformers:
  • Dissipation factor/ Power Factor/ Tan Delta and Capacitance of windings with frequency sweep and voltage sweep “tip-up”.
  • Dielectric frequency response analysis / DFRA /frequency dielectric spectroscopy / FDS
  • Partial discharge analysis.
  • Polarity check.
  • Ratio and phase accuracy.
  • Winding resistance.
  • Excitation characteristics (knee points).
  • Composite error (ALF, ALFi, FS, FSi, Vb).
  • Burden impedance.
  • Transient CT classes and parameters (TPS, TPX, TPY and TPZ type CTs).
  • Transient dimensioning factor (Ktd).
  • Burden.
  • Remanence and residual magnetism
  • Voltage transformers:
  • Dissipation factor/ Power Factor/ Tan Delta and Capacitance of windings with frequency sweep and voltage sweep “tip-up”.
  • Dielectric frequency response analysis / DFRA /frequency dielectric spectroscopy / FDS
  • Partial discharge analysis.
  • Ratio and phase accuracy.
  • Polarity check.
  • Winding resistance.
  • Burden.

Surge arrester:

  • Watt losses and total current.

Rotative machinery::

  • Dissipation factor/ Power Factor/ Tan Delta and Capacitance of windings with voltage sweep “tip-up”.
  • Insulation Resistance / Polarized Index / Polarization Depolarization Current Analysis / EDA.
  • Dielectric frequency response analysis / DFRA /frequency dielectric spectroscopy / FDS
  • Partial discharge analysis on-line and off-line.
  • Detection, pinpoint, and document of flash-arc corona and arcing partial discharge with camera UV.
  • Dielectric withstand test / Hi-pot.
  • Winding Resistance
  • Impulse winding test.
  • Frequency Response Analysis/ SFRA
  • Electromagnetic imperfection testing / CID.
  • Pole drop testing.
  • Insulation Resistance / Polarized Index.

Circuit Braker

  • Operation timing and contacts synchronism.
  • Motion / Contact travel: over-travel, total travel, rebound, damping time, contact wipe, …
  • Coil current.
  • Static contact resistance.
  • Insulation resistance
  • The SF6 gas quality: volume percentage, moisture concentration, SO2 concentration, HF concentration, H2S concentration and CO concentration.

SECTORES
• Electrical generation
• Transport ans distribution
• Chemical and petrochemical
• Automotive